title: "Evapotranspiration [1.0]"
description: "ZENTRA Cloud follows the standard FAO 56 Penman-Monteith guidelines for calculating evapotranspiration. Users can choose between ETr (alfalfa) reference or ETo (grass) reference depending on preference."
url: "https://docs.zentracloud.io/l/en/article/zlpd1t7hk2-evapotranspiration"
category: "Models"
updated_at: "2026-06-23T17:51:24Z"
language: "en"
---

# Evapotranspiration [1.0]

ZENTRA Cloud follows the standard [FAO 56 Penman-Monteith](https://www.fao.org/4/X0490E/x0490e06.htm) guidelines for calculating evapotranspiration. Users can choose between ETr (alfalfa) reference or ETo (grass) reference depending on preference.

#### Standardized Reference Evapotranspiration Equation:

[Chapter 2 - FAO Penman-Monteith](https://www.fao.org/4/X0490E/x0490e06.htm)

* * *

#### METER Sensors that support ET:

- [ATMOS 41](https://www.metergroup.com/environment/products/atmos-41-weather-station/)
- [ATMOS 41W](https://www.metergroup.com/en/meter-environment/products/atmos-41w-wireless-remote-weather-station)

OR a combination of

- [ATMOS 14](https://www.metergroup.com/environment/products/atmos-14/)/VP-4/VP3 - air temperature, vapor pressure.
- [Pyronometer](https://www.metergroup.com/environment/products/pyr-sensor/)- solar radiation
- [ATMOS 22](https://www.metergroup.com/environment/products/atmos-22-sonic-anemometer/)/DS-2 OR DAVIS CUP ANEMOMETER- wind speed.

* * *

#### ETo

- Click the **environmental model** icon.
- Select **ETo or ETr**.
- Enter a name for the model and a name for the chart.
- The default wind measurement height is 2 meters. Enter a custom value if needed.
- Select a device. The sensor inputs for **Wind Speed**, **Solar Radiation**, **Vapor Pressure** and **Air Temperature** will auto-populate. Select different sources for these inputs if necessary.
- Click **Create**.

![](https://files.helpdocs.io/la7ra8dc1e/articles/zlpd1t7hk2/1641423615510/eto-create-final.gif)

* * *

#### Accumulated ETo

- Click the **Vertical Ellipse** icon.
- Select Stats.
- Toggle the desired measurements.
- Click **Accept**.

![](https://files.helpdocs.io/la7ra8dc1e/articles/zlpd1t7hk2/1641423639582/eto-stats-final.gif)