# Module Identification

There are multiple ways to identify the radio module in your METER Group data logger. By the **Label**, via **Software**, or **Visual** inspection.

* * *

#### Label

You can identify the module type by checking the label located on the inside of the data logger door panel (ZL6, EM60G, EM50G), or by removing the rain funnel on the ATMOS 41W.

##### ZL6, EM60G, EM50G

- Open the data logger enclosure.
- Look for a label near the top of the inside door that lists the module name.

##### ATMOS 41W

- To remove the funnel, press the rain funnel down to compress the internal spring. Twist the funnel counter-clockwise to unlock it from the ATMOS 41W base.
- Look for a label on the side of the ATMOS 41W base.

![Figure 1: Example sticker label](https://files.helpdocs.io/la7ra8dc1e/articles/tp46e0covx/1763752534236/sticker-example.png)

* * *

#### Software

##### ZENTRA Utility Mobile

You can identify the Module Type, SIM Type, and Profile with ZENTRA Utility Mobile (ZL6, ATMOS 41W, EM60G).

- Press the **Test** button on the data logger to activate the Bluetooth communications.
- Open **ZENTRA Utility Mobile**.
- Tap the device on the **Connect** screen to connect to it.
- Tap **More** in the **Navigation** bar.
- Select **Device Tools**.
- Select **Update Communication Hardware**.

The **Update Communications Hardware** screen will display the **Module Type**, **SIM Type**, and **Profile** configuration for the hardware.

![](https://files.helpdocs.io/la7ra8dc1e/articles/tp46e0covx/1760130334360/zentra-utility-mobile-module-type.png)

* * *

##### ZENTRA Utility

You can identify the Module Type and SIM Number with ZENTRA Utility (ZL6, ATMOS 41W, EM60G).

- Plug in the **USB to Micro-USB** cable between your laptop and the data logger.
  
  - The COM port should list the connected device.
- Click the **Connect** button to connect to the device currently selected in the COM port dropdown menu. If the device fails to connect, click the COM port dropdown to select a different device.
- Click **Settings** in the toolbar.
- Click the **Communication** Settings tab.
- The **Communication Settings** tab will display the **Module Type** and **SIM** number.

![](https://files.helpdocs.io/la7ra8dc1e/articles/tp46e0covx/1760127038777/zentra-utility-module-type.png)

* * *

##### ZENTRA Cloud

You can identify the Module Type and SIM Number with ZENTRA Cloud (ZL6, ATMOS 41W, EM60G, EM50G).

- Log in to zentracloud.com
- Click **Device Configuration** from the devices menu.
- Click the **Communication Settings** tab.
- Scroll to the bottom of the page.

The Communication Settings tab will display the **Module Type** and **SIM** number.

![](https://files.helpdocs.io/la7ra8dc1e/articles/tp46e0covx/1760126641242/zentra-cloud-module-type.png)

* * *

#### Visual

You can disassemble the data logger to visually identify the installed hardware.

##### ZL6, EM60G

- **Disassemble**
  
  - Remove the four screws holding the **Printed Circuit Board** (PCB) to the data logger case.
  - Flip the PCB board over to look at the back.

##### ATMOS 41W

- **Disassemble**
  
  - To remove the funnel, press the rain funnel down to compress the internal spring. Twist the funnel counter-clockwise to unlock it from the ATMOS 41W base.
  - Unscrew the battery cap and gently unplug the battery pack wire.
  - Unscrew the rain gauge assembly and turn it on its side to look at the PCB board underneath.

*Module Types: ZL6, EM60G, ATMOS 41W*

| Module | Wireless Technology |
|--------|---------------------|
| LISA   | 3G                  |
| SARA   | 4G                  |
| LARA   | 4G                  |
| NINA   | Wi-Fi               |

![](https://files.helpdocs.io/la7ra8dc1e/articles/tp46e0covx/1764112808878/lisa-sara-nina-lara.png)

##### EM50G

- **Disassemble**
  
  - Remove the four screws holding the **Printed Circuit Board** (PCB) to the data logger case.
  - Flip the PCB board over to look at the back.

*Module Types: EM50G*

| Module | Wireless Technology |
|--------|---------------------|
| G24    | 2G                  |
| H24    | 3G                  |

![](https://files.helpdocs.io/la7ra8dc1e/articles/tp46e0covx/1760125761598/module-type-g-24-h-24.png)