# AT&T / T-Mobile and Worldwide H1 Terminal Commands

**Use the wizard instead.** The [Module Swap Wizard](https://docs.zentracloud.io/l/en/article/d59m50oali-module-swap-wizard) in **ZENTRA Utility on mobile** detects your installed hardware, applies the correct settings, and verifies the connection to ZENTRA Cloud for you. Only use the commands on this page if the **desktop version of ZENTRA Utility** is the only one you have access to. To return to the full procedure, see the [AT&T / T-Mobile Configuration Guide](https://docs.zentracloud.io/l/en/article/x3w5e1ndle-module-install-for-att-tmobile) or the [Worldwide H1 SIM Configuration Guide](https://docs.zentracloud.io/l/en/article/k14s7pt7v4-module-install-for-worldwide).

These commands apply to AT&T, T-Mobile, and Worldwide H1 configurations, which use the same settings. For Verizon, see [*Verizon Terminal Commands*](/l/en/article/hgpmay4rbr-verizon-terminal-commands).

##### Requirements

The correct **module**. See [Module Identification](https://docs.zentracloud.io/l/en/article/tp46e0covx-datalogger-module-identification).

##### Steps

1. **Connect**
   
   1. Connect via a cabled connection.
2. **Terminal**
   
   1. Click **Terminal** in the **Menu** bar to open the terminal window.
3. **Check the trait**
   
   1. Type `get trait` and press enter.
   2. If the response is "2", the device is already configured for cellular. Continue to the next step.
   3. If the response is anything else, type `set trait 2` and press enter. The response in the terminal should be "OK".
   4. Type `get trait` again to confirm the response is now "2".
4. **Check the APN**
   
   1. Type `get apn` and press enter.
   2. If the response is "h.meter.apn", continue to the next step.
   3. If the response is anything else, type `set apn h.meter.apn` and press enter. The response in the terminal should be "OK".
   4. Type `get apn` again to confirm the response is now "h.meter.apn".
5. **Check the profile**
   
   1. Type `get profile` and press enter.
   2. If the response is "201", continue to the next step.
   3. If the response is anything else, type `set profile 201` and press enter. The response in the terminal should be "OK".
   4. Type `get profile` again to confirm the response is now "201".
6. **Test**
   
   1. Disconnect the logger from ZENTRA Utility and then re-connect.
   2. Run a [communication test](https://docs.zentracloud.io/l/en/article/3vfi22ix67-zentra-utility) to verify connectivity with the network.