title: "GET Device Data"
description: "Pull time-series measurements for a single device with GET /v5/devices/{device_id}/data — parameters, response schema, date and reading-ID paging, and code examples."
url: "https://docs.zentracloud.io/l/en/article/pep98lcz1h-get-device-readings"
category: "v5.0"
updated_at: "2026-11-05T19:46:33Z"
language: "en"
---

# GET Device Data

`GET /v5/devices/{device_id}/data`

Retrieves time-series measurements for a single device. Get the `device_id` from [List Devices](/l/en/article/7t31rdmwh4-list-devices), then call this endpoint to pull the device's readings over a date range, timestamp range, relative window, or reading ID. Set `aggregate` to hourly or daily to get `hourly` or `daily` summaries for every sensor on the device instead of its interval readings.

[Get device data | ZENTRA Cloud](https://www.youtube.com/embed/j6uFK3Tj2qQ?feature=oembed)

#### Authentication

Authenticated with your API key in the `X-API-Key` header; the user is resolved from the key. Access requires an Administrator, Editor, or User role in the device's organization. See [Authentication](/l/en/article/zjky832943-api-v5) and [Data access control](/l/en/article/zjky832943-api-v5) in the Overview.

Explore the interactive v5 endpoint in the [OpenAPI/Swagger](https://api.zentracloud.io/) reference.

#### Request

GET https://api.zentracloud.io/v5/devices/{device\_id}/data

#### Path parameters

| Parameter   | Type   | Required | Description                                               |
|-------------|--------|----------|-----------------------------------------------------------|
| `device_id` | string | Yes      | The unique identifier of the device. Example: `z6-12345`. |

#### Query Parameters

| Parameter          | Type              | Default      | Description                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        |
|--------------------|-------------------|--------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| `direction`        | string            | `descending` | Order in which data is retrieved and displayed by date. One of `ascending` or `descending`. Ignored when `since_reading_id` is supplied.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           |
| `start_datetime`   | string (ISO 8601) | \-           | Start of the window as an ISO datetime string. A datetime without a timezone is treated as UTC. Example: `2025-10-20T17:15+00:00`. Use window **or** datetimes **or** timestamps — only one.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                       |
| `end_datetime`     | string (ISO 8601) | \-           | End of the window as an ISO datetime string. A datetime without a timezone is treated as UTC. Example: `2025-10-20T17:15+00:00`. Use window **or** datetimes **or** timestamps — only one.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         |
| `start_timestamp`  | integer           | \-           | Start of the window as a Unix timestamp (seconds since 1970-01-01 UTC). Example: `1763445086`. Use window **or** datetimes **or** timestamps — only one.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           |
| `end_timestamp`    | integer           | \-           | End of the window as a Unix timestamp (seconds since 1970-01-01 UTC). Example: `1763445086`. Use window **or** datetimes **or** timestamps — only one.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                             |
| `window`           | string            | \-           | A relative time range measured back from the time of the request (server time, UTC). Written as `<n><unit>`, where `<n>` is a positive whole number and `<unit>` is `m` (minutes), `h` (hours), `d` (days), or `w` (weeks). Example: `24h` for the last 24 hours. Must resolve to one year or less — the maximum is `365d` or `52w`. Use a window **or** datetimes **or** timestamps — only one.                                                                                                                                                                                                                                                                                                                                                                                                                   |
| `since_reading_id` | integer           | \-           | Start of the window as a reading ID, exclusive — the response begins at the next ID after this value, so `40` returns a first `reading_id` of `41`. Must be `0` or greater; `0` starts from the earliest reading still retrievable for the device. Results are ordered ascending by `reading_id`, then by `port_num`. Takes precedence over `direction`, `start_datetime`, `end_datetime`, `start_timestamp`, `end_timestamp`, `window`, and `next_token`, which are ignored without error when it is supplied. The exception is `aggregate`: combining `since_reading_id` with `aggregate=hourly` or `aggregate=daily` returns 422. `aggregate=raw`, the default, can be passed explicitly alongside it. Pass `next_reading_id` from the previous response to continue. See Reading IDs and complete pulls below. |
| `units`            | string            | `metric`     | Unit system for returned values, each value's position, and `metadata.elevation`. One of `metric` or `imperial`. Measurements that use the same unit in both systems (kPa, mS/cm, W/m²) are returned unconverted. Each value's unit field reports the unit applied.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                |
| `aggregate`        | string            | `raw`        | Aggregation level of the returned rows. One of `raw`, `hourly`, or `daily`. `raw` returns interval readings. `hourly` and `daily` return one summary row per series per bin, and each row's `stat` names the statistic held in `value`. Works with `units`, `direction`, `window`, and either explicit range pair. Cannot be combined with `since_reading_id` ; doing so returns 422. See Aggregated readings below.                                                                                                                                                                                                                                                                                                                                                                                               |
| `next_token`       | string            | \-           | The token needed to retrieve the next pagination set. See Pagination below. Ignored when `since_reading_id` is supplied.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           |

Choose one way to specify the time range: the datetime pair (`start_datetime` / `end_datetime`), the timestamp pair (`start_timestamp` / `end_timestamp`), or a relative `window`. Combining them returns `422`. If you send none of them, the request returns the last 14 days, the same as `window=14d`. When you send both datetimes, they must carry the same UTC offset, or the request returns `422`. Offsets are compared by value, so `Z` matches `+00:00` and two datetimes without an offset match each other, but a datetime without an offset does not match `Z`. Across a daylight saving time (DST) change, write both ends in one offset: `2026-11-04T23:59:00-08:00` is the same moment as `2026-11-05T00:59:00-07:00`. The timestamp pair has no offset, so the rule doesn’t apply to it.

Measurements are retained for 914 days. A time range that reaches back further than that is shortened to the retention cutoff rather than rejected. See Data retention in the [v5 API Overview](/l/en/article/zjky832943-api-v5).

`since_reading_id` sits outside this rule. It is not rejected alongside the other time-range parameters; it overrides them silently. Supply it and the response is ordered by reading ID regardless of what else you sent, with `direction`, both datetime parameters, both timestamp parameters, `window`, and `next_token` ignored and no 422 returned. The one exception is `aggregate=hourly` or `aggregate=daily`, which cannot be combined with `since_reading_id` and returns 422.

A `window` value must be a positive whole number followed by a single lowercase unit character. Any other form — decimals, negatives, zero, uppercase units, long unit names, whitespace, or a bare number — returns `422`.

### Example requests

#### cURL

```
curl --request GET \
  --url 'https://api.zentracloud.io/v5/devices/z6-00930/data?start_datetime=2026-05-29T00%3A00%3A00-00%3A00&end_datetime=2026-05-30T23%3A59%3A00-00%3A00&direction=descending&units=metric' \
  --header 'Accept: */*' \
  --header 'X-API-Key: YOUR_API_KEY'
```

```
curl --request GET \
  --url 'https://api.zentracloud.io/v5/devices/z6-00930/data?window=24h&direction=descending&units=metric' \
  --header 'Accept: */*' \
  --header 'X-API-Key: YOUR_API_KEY'
```

```
curl --request GET \
--url 'https://api.zentracloud.io/v5/devices/z6-00930/data?window=7d&aggregate=daily&units=metric' \
--header 'Accept: */*' \
--header 'X-API-Key: YOUR_API_KEY'
```

Paging by reading ID. The first request starts from the earliest retrievable reading.

```
curl --request GET \
  --url 'https://api.zentracloud.io/v5/devices/z6-00930/data?since_reading_id=0&units=metric' \
  --header 'Accept: */*' \
  --header 'X-API-Key: YOUR_API_KEY'
```

The response returns a `next_reading_id`. Send it back as `since_reading_id` to continue:

```
curl --request GET \
  --url 'https://api.zentracloud.io/v5/devices/z6-00930/data?since_reading_id=27116&units=metric' \
  --header 'Accept: */*' \
  --header 'X-API-Key: YOUR_API_KEY'
```

#### JavaScript — Fetch

```
const url = 'https://api.zentracloud.io/v5/devices/z6-00930/data?start_datetime=2026-05-29T00%3A00%3A00-00%3A00&end_datetime=2026-05-30T23%3A59%3A00-00%3A00&direction=descending&units=metric';
const options = {
  method: 'GET',
  headers: { 'X-API-Key': 'YOUR_API_KEY', Accept: '*/*' }
};

try {
  const response = await fetch(url, options);
  const data = await response.json();
  console.log(data);
} catch (error) {
  console.error(error);
}
```

#### Python — Requests

```
import requests

url = "https://api.zentracloud.io/v5/devices/z6-00930/data"
querystring = {
    "start_datetime": "2026-05-29T00:00:00-00:00",
    "end_datetime": "2026-05-30T23:59:00-00:00",
    "direction": "descending",
    "units": "metric",
}
headers = {
    "X-API-Key": "YOUR_API_KEY",
    "Accept": "*/*",
}

response = requests.get(url, headers=headers, params=querystring)
print(response.json())
```

#### PHP — cURL

```
<?php
$curl = curl_init();

curl_setopt_array($curl, [
    CURLOPT_URL => "https://api.zentracloud.io/v5/devices/z6-00930/data?start_datetime=2026-05-29T00%3A00%3A00-00%3A00&end_datetime=2026-05-30T23%3A59%3A00-00%3A00&direction=descending&units=metric",
    CURLOPT_RETURNTRANSFER => true,
    CURLOPT_CUSTOMREQUEST => "GET",
    CURLOPT_HTTPHEADER => [
        "Accept: */*",
        "X-API-Key: YOUR_API_KEY",
    ],
]);

$response = curl_exec($curl);
$err = curl_error($curl);
curl_close($curl);

if ($err) {
    echo "cURL Error #:" . $err;
} else {
    echo $response;
}
```

#### R — httr

```
library(httr)

url <- "https://api.zentracloud.io/v5/devices/z6-00930/data"

queryString <- list(
  start_datetime = "2026-05-29T00:00:00-00:00",
  end_datetime   = "2026-05-30T23:59:00-00:00",
  direction      = "descending",
  units          = "metric"
)

response <- VERB("GET", url, query = queryString,
                 add_headers('X-API-Key' = 'YOUR_API_KEY'),
                 accept("*/*"))

content(response, "text")
```

#### Response

A `200 OK` returns five top-level fields: `metadata` about the device, the `values` for the requested window, `pagination` with a `next_token` or `next_reading_id` when more pages are available, `sensor_errors` listing sensor-status faults currently detected on the device's ports, and `error_codes` describing every error code that appears in `values` or `sensor_errors`.

Example Response

```
"metadata": {
  "device_id": "z6-01455",
  "device_name": "Market Logger",
  "location": "Market Place",
  "coordinates": "46.7525833, -117.1819223",
  "elevation": 774.0,
  "elevation_unit": "m",
  "reading_id_max_available": 89116,
  "aggregate": "raw",
  "timezone": null
},
```

```
"pagination": { ...unchanged... },
"sensor_errors": [],
"error_codes": {
  "0": "No error"
}
```

`metadata`

Describes the device the readings belong to.

| Field                      | Type            | Description                                                                                                                                                                                                                                                                                                   |
|----------------------------|-----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| `device_id`                | string          | The unique identifier (serial) of the device.                                                                                                                                                                                                                                                                 |
| `device_name`              | string          | The device's display name. Defaults to the `device_id` when no custom name is set.                                                                                                                                                                                                                            |
| `location`                 | string          | The folder path the device sits in, for example `Zone/Farm/Plot` etc.                                                                                                                                                                                                                                         |
| `coordinates`              | string          | The device's latitude and longitude, comma-separated.                                                                                                                                                                                                                                                         |
| `elevation`                | number \| null  | The device's current elevation, rounded to a whole number: the location override if one is set, otherwise the latest GPS altitude. This is the device's elevation today, not at the time of any measurement. Expressed in `elevation_unit`. `null` when the location override has no elevation.               |
| `elevation_unit`           | string          | The unit elevation is expressed in: m for `units=metric`, ft for `units=imperial`. Always present, even when elevation is null.                                                                                                                                                                               |
| `reading_id_max_available` | integer \| null | The highest `reading_id` currently assigned to this device, or `null` when the device has no readings. Returned on every request, not only when paging by reading ID. Compare it against the last `reading_id` you received to see how far behind you are.                                                    |
| `timezone`                 | string \| null  | The IANA timezone that hourly and daily bins are cut in, for example `America/Los_Angeles`: the device's timezone override if one is set, otherwise the organization's timezone. The UTC offset in each row's `datetime` follows this zone. `null` on `raw` responses, including `since_reading_id` requests. |
| `aggregate`                | string          | The aggregation level applied to this response: `raw`, `hourly`, or `daily`. Returned on every response, including requests that didn't supply `aggregate`.                                                                                                                                                   |

`values []`

Each item is a single measurement from one sensor port at one point in time, or, in an aggregated response, a summary of one series over one bin. A series is identified by `port_num`, `measurement`, `sensor_name`, and `position` together. Multi-depth sensors such as TEROS 54 and TEROS 06 report one series per depth on the same port, told apart only by `position`. In a time-range request, entries are grouped by series and ordered by time within each series, following the `direction` parameter; in an aggregated response, that is each bin's start (`timestamp`). The order of the series themselves is not guaranteed.

When `since_reading_id` is supplied, entries are ordered by `reading_id` ascending and then by `port_num`, and computed ET measurements (Hourly and Daily Reference ET and Actual ET) are not returned.

| Field         | Type            | Description                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           |
|---------------|-----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| `port_num`    | integer \| null | The sensor port the reading came from. `null` for logger-level readings such as Signal Strength, which have no physical port; identify those by measurement.                                                                                                                                                                                                                                                                                                                                                                                          |
| `measurement` | string          | The measured quantity (e.g. `Gust Speed`).                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            |
| `unit`        | string          | The unit of `value`, reflecting the requested units (e.g. m/s). Measurements that have no unit, such as NDVI, PRI, counts, ratios, and dielectric permittivity, return an empty string "", never null.                                                                                                                                                                                                                                                                                                                                                |
| `sensor_name` | string          | The sensor that produced the reading (e.g. `ATMOS 41W`).                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              |
| `position`    | number \| null  | The sensor position this value was measured at, in cm for `units=metric` or in for `units=imperial`. Negative is below ground (a depth); positive is above ground (a height). `null` when the port has no position set.                                                                                                                                                                                                                                                                                                                               |
| `value`       | number \| null  | The measured value, rounded to the measurement's display precision in the returned unit — the same precision the ZENTRA Cloud app and in-app download use. Precision depends on the sensor and the unit: each measurement has a sensor-defined number of decimal places, which some unit conversions adjust (for example, air temperature is reported to 0.1 degree in both °C and °F). On `hourly` and `daily` rows, the statistic named by `stat`, rounded to the same precision as that measurement's raw readings. `null` when there is no value. |
| `timestamp`   | integer         | The reading time as a Unix timestamp (seconds since the epoch, UTC). On `hourly` and `daily` rows, the start of the bin the row summarizes.                                                                                                                                                                                                                                                                                                                                                                                                           |
| `datetime`    | string          | The reading time as a human-readable datetime with UTC offset. On `hourly` and `daily` rows, the start of the bin the row summarizes.                                                                                                                                                                                                                                                                                                                                                                                                                 |
| `error_code`  | integer         | `0` when the sensor is reporting normally. Any other value indicates a problem; look it up in [Device & Sensor Error Codes](https://docs.zentracloud.io/l/en/article/l1uopg3wo7-device-sensor-error-codes).                                                                                                                                                                                                                                                                                                                                           |
| `reading_id`  | integer \| null | The identifier of the reading this entry came from. Every entry produced by the same reading carries the same value — one reading commonly produces dozens of entries. `null` on computed ET measurements (Hourly and Daily Reference ET and Actual ET), which are computed over a period rather than belonging to a single reading, and on every row of an `hourly` or `daily` response.                                                                                                                                                             |
| `stat`        | string          | The statistic `value` holds: `sum`, `mean`, `max`, `min`, or `last`. Present only on `hourly` and `daily` rows. See Aggregated readings below.                                                                                                                                                                                                                                                                                                                                                                                                        |

**Aggregated readings**

[Get hourly and daily summaries | ZENTRA Cloud](https://www.youtube.com/embed/MFOFo2R8lvg?feature=oembed)

`aggregate=hourly` and `aggregate=daily` return one summary row per series per bin in place of interval readings. Each row's `stat` names the statistic in `value`:

- `sum` for accumulating measurements such as precipitation, evapotranspiration, and lightning counts.
- `mean` for averaged measurements such as temperature and water content.
- `max` for max-type measurements such as solar radiation.
- `min` for min-type measurements.
- `last` for everything else.

A row's `timestamp` and `datetime` mark the start of its bin, and a range selects the bins whose start falls within it. A bin that started before your range begins is not returned, even if it overlaps the range. For example, `window=7d` resolved at 14:00 leaves out the bin for the day the window starts in. To get whole local days, use an explicit range that starts at local midnight and includes the device's UTC offset. Both datetimes must carry the same offset, so if the range crosses a DST change, write the end in the start’s offset. For Oct 28 through Nov 4, 2026 in America/Los\_Angeles, send start\_datetime=2026-10-28T00:00:00-07:00&end\_datetime=2026-11-05T00:59:00-07:00; the end is 23:59 on Nov 4 local time. A datetime without a timezone is treated as UTC.

Bins follow local clock boundaries in the device's timezone (its override if one is set, otherwise the organization's), which is reported in `metadata.timezone`. A daily bin is one local calendar day, so it spans 23 or 25 hours on a DST transition day. The most recent bin may still be accumulating, and its value can change until the bin closes.

If the device's measurement interval is equal to or longer than the bin size, no aggregates exist at that level and `values` is empty. The API does not fall back to interval readings. A device that measures hourly returns nothing for `aggregate=hourly`.

Aggregate rows have `reading_id: null` and honor `units`. Aggregate requests page by calendar month like raw requests, and they are clamped to the same retention cutoff. They cannot be combined with `since_reading_id` (422). To pull aggregates, use a time range or window rather than a reading ID.

Each aggregate row reports its statistic over the valid samples in the bin and carries the `error_code` of the bin's last sample. A row can therefore carry a `value` alongside a non-zero `error_code`. The reverse also holds: `error_code: 0` on an aggregate row means the last sample was valid, not that every sample in the bin was.

If every sample in a bin was in error, the row is still returned with the last sample's non-zero `error_code`, and its `value` can be `null` or `0.0`. `sum` rows (precipitation, evapotranspiration, lightning counts) return `0.0`, so check `error_code` before treating a `0.0` as a measured zero. A bin with no samples at all returns no row.

**Error codes and missing values.**

`error_code` is the authoritative signal that something was wrong with a measurement. A non-zero `error_code` is a sensor-level condition, not a transport error. Do not infer it from `value`, in either direction.

A row with a non-zero `error_code` may still carry a number. Individual sensor readings that error usually come back with `value: null`, but that is a convention of how readings are written rather than something the response guarantees. Two kinds of row depart from it by design:

- **Computed ET measurements.** A date-range request also returns Hourly and Daily Reference ET and Actual ET, identifiable by the Hourly or Daily prefix on `measurement` and by `reading_id: null`. These carry the error code from the last reading in the period alongside a value computed from the readings that were valid. If every reading in the period errored, the value can come back as `0.0`, which is indistinguishable from a genuine zero.
- **Aggregate rows.** `hourly` and `daily` rows report statistics over the valid samples in the bin and carry the last sample's code. See Aggregated readings above.

Equally, `value: null` is not by itself an error signal. Read a non-zero `error_code` as "there was a problem with this measurement." On a computed ET measurement or an aggregate row, read it as "the most recent reading in this period had a problem."

Slow-moving sensor-status faults, such as Sensor Offline, Refill Required, and Auto-pump Low Battery (codes `100`–`127`), are decoded from sensor metadata rather than from a reading. They never appear on a value. They are reported in `sensor_errors` instead.

`sensor_errors`

Sensor-status faults currently detected on the device's ports, such as Sensor Offline, Refill Required, and Auto-pump Low Battery (codes `100`–`127`). These are decoded from sensor metadata rather than from a reading, so they never appear as an `error_code` in `values`.

The list reflects the device's current status, not the requested time range. A request for last year's data returns the faults detected today. `sensor_errors` is present on every response; it is an empty array when no faults are detected. Each fault on a port is its own entry, and entries are sorted by `port_num`, then by `error_code`. Informational states such as Auto-pump In-Line are not listed, and neither are ports with no sensor configured or whose sensor has since changed.

| Field         | Type    | Description                                                                                                                                                                                                                                                                                                                              |
|---------------|---------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| `port_num`    | integer | The port of the sensor reporting the fault.                                                                                                                                                                                                                                                                                              |
| `sensor_name` | string  | The sensor reporting the fault, for example `TEROS 32`.                                                                                                                                                                                                                                                                                  |
| `error_code`  | integer | A code in the `100`–`127` range naming the fault. Its description is in `error_codes`.                                                                                                                                                                                                                                                   |
| `timestamp`   | integer | When ZENTRA Cloud last detected this sensor's status, in Unix seconds. For most sensors this is when the device last reported the sensor's status; for ATMOS 41 Gen 2, ATMOS 41W, ATMOS 51, and ATMOS 31, it is the latest reading that refreshed it. It is not the time a value was measured, and not necessarily when the fault began. |
| `datetime`    | string  | The same instant as a human-readable datetime, with the UTC offset of the device's timezone (its override if one is set, otherwise the organization's).                                                                                                                                                                                  |

`error_codes`

A lookup of the error codes present in this response. Each key is an `error_code` (as a string) that appears in `values` or `sensor_errors`, and each value is its catalog description. `0` is always "No error". See [Device & Sensor Error Codes](/l/en/article/l1uopg3wo7-device-sensor-error-codes) for the full list.

```
"error_codes": {
  "0": "No error",
  "137": "Invalid Value"
}
```

`pagination`

| Field             | Type                      | Description                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                 |
|-------------------|---------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| `num_readings`    | integer                   | The number of distinct readings with at least one entry in `values` on this page. When paging with `since_reading_id`, it can be smaller than the number of reading IDs the page moved past, because some IDs have no data you can see; use `next_reading_id`, not `num_readings`, to track your position. In an `hourly` or `daily` response, it is the number of bins in the series with the most bins on this page, including bins whose `value` is `null`. It is not the number of entries in `values`. Do not treat it as a page size. |
| `next_token`      | string \| null            | The token to pass on the next request to fetch the following page, or `null` when there are no more pages. See Pagination below. `null` in a cursor response — reading-ID paging uses `next_reading_id` instead.                                                                                                                                                                                                                                                                                                                            |
| `start_datetime`  | string (ISO 8601) \| null | The start of the window covered by this page. `null` in a cursor response, which is not bounded by a time window.                                                                                                                                                                                                                                                                                                                                                                                                                           |
| `end_datetime`    | string (ISO 8601) \| null | The end of the window covered by this page. `null` in a cursor response, which is not bounded by a time window.                                                                                                                                                                                                                                                                                                                                                                                                                             |
| `next_url`        | string \| null            | A ready-to-use URL that fetches the next page. Follow it exactly as given. `null` on the last page.                                                                                                                                                                                                                                                                                                                                                                                                                                         |
| `next_reading_id` | integer \| null           | The cursor to send as `since_reading_id` on the next request. `null` when no readings remain, and `null` on any request that did not use `since_reading_id`.                                                                                                                                                                                                                                                                                                                                                                                |

**Example response**

```
{
  "metadata": {
    "device_id": "z6-01455",
    "device_name": "Market Logger",
    "location": "Market Place",
    "coordinates": "46.7525833, -117.1819223",
    "elevation": 774.0,
    "elevation_unit": "m",
    "reading_id_max_available": 89116
  },
  "values": [
    {
      "port_num": 6,
      "measurement": "Water Content",
      "unit": "m³/m³",
      "sensor_name": "TEROS 54",
      "position": -15.0,
      "value": 0.338,
      "timestamp": 1788393600,
      "datetime": "2026-09-02T17:00:00-07:00",
      "error_code": 0,
      "reading_id": 89024
    },
    {
      "port_num": 6,
      "measurement": "Water Content",
      "unit": "m³/m³",
      "sensor_name": "TEROS 54",
      "position": -15.0,
      "value": 0.338,
      "timestamp": 1788394500,
      "datetime": "2026-09-02T17:15:00-07:00",
      "error_code": 0,
      "reading_id": 89025
    },
    // ... the remaining readings in this series, then the other measurement series
    {
      "port_num": 2,
      "measurement": "Hourly Reference ET",
      "unit": "mm",
      "sensor_name": "ATMOS 41 G2",
      "position": null,
      "value": 0.11,
      "timestamp": 1788393600,
      "datetime": "2026-09-02T17:00:00-07:00",
      "error_code": 0,
      "reading_id": null
    },
    {
      "port_num": null,
      "measurement": "Signal",
      "unit": "%",
      "sensor_name": "Signal Strength",
      "position": null,
      "value": 84.0,
      "timestamp": 1788397200,
      "datetime": "2026-09-02T18:00:00-07:00",
      "error_code": 0,
      "reading_id": 89028
    }
  ],
  "pagination": {
    "num_readings": 5,
    "next_token": null,
    "next_url": null,
    "next_reading_id": null,
    "start_datetime": "2026-09-03T00:00:00Z",
    "end_datetime": "2026-09-03T01:00:00Z"
  },
  "error_codes": {
    "0": "No error"
  }
}
```

In a time-range response `num_readings` counts readings, not entries in `values[]`. The response above reports 5 readings and contains 294 entries, because this device reports 58 measurements per reading.

`reading_id_max_available` is `89116` while the last reading returned is `89028`, so this device holds a further 88 readings outside the requested hour.

#### Pagination

The simplest way to page is to follow `next_url`. It already carries the correct path, your choices such as `units` and `direction`, and the new token — so you do not have to rebuild the URL yourself. Keep following it until it comes back `null`.

[Page through readings | ZENTRA Cloud](https://www.youtube.com/embed/MHVKKo6Oi2o?feature=oembed)

`next_url` deliberately leaves out the time-window parameters (`start_datetime`, `end_datetime`, `start_timestamp`, `end_timestamp`, and `window`). The token already encodes the remaining window and the sort direction, so carrying the original time parameters forward would conflict with it. Because `window` resolves against the server clock at request time, this also means a paged window is fixed at the first request and does not shift as you follow `next_url`.

An empty page does not mean you are finished. A response can carry `values: []` and `num_readings: 0` and still have more pages behind it — the window it covered simply held no data. Only a `null` cursor ends the walk: `next_token: null` when paging by token, `next_reading_id: null` when paging by reading ID.

If you would rather build requests yourself, pass the returned `next_token` back as the `next_token` parameter.

When you page with `since_reading_id`, `next_url` carries `since_reading_id` in place of `next_token`, so following it works exactly the same way. To build the request yourself instead, take `next_reading_id` from the response and send it as `since_reading_id`. Paging is finished when `next_reading_id` comes back `null`.

When requesting data in descending order (newest first), the first page contains only the portion of the current month up to your requested `end_datetime` or `end_timestamp`. As a result, this initial page is often smaller than subsequent pages, which each contain a full calendar month of data. A request that starts mid-month ends its first page at the month boundary, not 30 days later.

A cursor page covers 30 days of the device's timeline from the first reading after your cursor, however many readings that turns out to be.

Reading-ID pages are not small. A device reporting every 15 minutes across a dozen sensors produces well over 100,000 entries in a single 30-day page — tens of megabytes, and several seconds to return. Stream or page incrementally rather than holding a full history pull in memory.

#### Reading IDs and complete pulls

Every reading a device uploads is assigned a `reading_id`. The sequence belongs to the device, increases by one per reading, and never skips a value. IDs are assigned in the order readings arrive at ZENTRA Cloud, which is not necessarily the order they were measured — a logger uploading backfilled data receives new IDs for older measurements.

[Copy a device's full history | ZENTRA Cloud](https://www.youtube.com/embed/madK-MlWn5c?feature=oembed)

One reading normally produces several entries in `values[]`, one per sensor measurement, and every entry carries that reading's `reading_id`. Repeated IDs down the array are expected. In a cursor response these entries are ordered by `reading_id`, then by `port_num`.

To take a complete copy of a device's history, page on `since_reading_id` rather than on dates. Start at `0`, take `next_reading_id` from each response, and pass it as `since_reading_id` on the next request, until `next_reading_id` comes back `null`. `metadata.reading_id_max_available` is the highest ID the device currently holds, so you can compare it against the last ID you received at any point to see how far behind you are.

Because IDs follow arrival rather than measurement time, this is also the reliable way to poll for new data. A date-based query for "everything since yesterday" misses readings that arrived today carrying older timestamps. A cursor picks them up, because they were assigned new IDs when they arrived.

`next_reading_id` comes back `null` on the last page that still holds readings, so the response leaves you no cursor to keep between polls. Save the highest `reading_id` you have stored, and send it as `since_reading_id` to start the next poll. Use that ID, not `metadata.reading_id_max_available`, which tells you how far behind you are, not where you stopped. If nothing new has arrived, the response is `200` with an empty `values` and `next_reading_id: null`.

`since_reading_id` is exclusive and applies to the whole reading: `since_reading_id=27115` returns nothing from reading `27115` and begins at `27116`.

**A missing ID in** `values[]` **does not mean missing data.** A reading whose measurements cannot be resolved against your organization's sensor configuration is still counted by the cursor but produces no entries, so its ID will not appear in the output. The cursor guarantees you were offered every reading — not that every ID is represented in what you received.

The sequence does not necessarily reach back to a device's first-ever measurement. A device that predates the v5 data store has readings older than its lowest retrievable `reading_id`, and those are not available through this endpoint.

#### Rate limiting

Rate-limited per device, not per user. The budget belongs to the device and is shared by every client reading it, so another integration polling the same device can exhaust it. A 429 includes a Retry-After header with the number of seconds to wait. See [Rate Limiting](/l/en/article/f6wdg770d3-rate-limiting).

#### HTTP Status Codes

| Status | Endpoint-specific cause                                                                                                                                                                                                                                                                                                                                                                                                                                       |
|--------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| `403`  | You lack an Administrator, Editor, or User role in the device's organization.                                                                                                                                                                                                                                                                                                                                                                                 |
| `404`  | The device does not exist, or you have workspace-only access and the device is not shared into any of your workspaces. A 404 does not always mean the serial number is wrong.                                                                                                                                                                                                                                                                                 |
| `422`  | Mixing `window` with datetime or timestamp parameters, mixing datetime and timestamp parameters, a `start_datetime` and `end_datetime` with different UTC offsets or with an offset on only one of them, a `window` that resolves to more than one year, a malformed `window` value, a `since_reading_id` below 0 or not a whole number, combining `aggregate=hourly` or `aggregate=daily` with `since_reading_id` , or an otherwise invalid parameter value. |

See [HTTP Status Codes](/l/en/article/ajte070y7e-errors) for the full model, including `401` and `429`.

#### Notes

- Carry the `device_id` from [List Devices](/l/en/article/7t31rdmwh4-list-devices) into the path.
- Timestamps are seconds since the Unix epoch (UTC).
- To take a complete copy of a device's history, or to catch readings that arrived after their measurement time, page with `since_reading_id` rather than by date.
- Aggregate rows have no reading ID. Pull `hourly` and `daily` summaries with a time range or `window`, not `since_reading_id`.