title: "Wet Bulb Temperature"
description: "How ZENTRA Cloud calculates wet-bulb temperature from air temperature, humidity, and pressure, and how to create the model."
url: "https://docs.zentracloud.io/l/en/article/1bn8krwfsc-wet-bulb-temperature"
category: "Environmental Models"
updated_at: "2026-10-20T20:35:05Z"
language: "en"
---

# Wet Bulb Temperature

Wet Bulb Temperature is the lowest temperature that evaporation of water into the air can cool a wet surface to. It combines air temperature and humidity in one value. In dry air it sits well below air temperature, because evaporation has a lot of room to cool. In saturated air it equals air temperature, because no further evaporation is possible.

ZENTRA Cloud also uses this value as one input to [Wet Bulb Globe Temperature (WBGT)](https://docs.zentracloud.io/l/en/article/uiwwdflele-heat-stress-wbgt-2-0).

This model is not yet available to general users.

![](https://files.helpdocs.io/la7ra8dc1e/articles/1bn8krwfsc/1792528502187/echarts-3.png)

##### Supported sensors

Wet Bulb Temperature can be calculated from one sensor that reports air temperature, humidity, and atmospheric pressure. All three inputs must come from the same sensor; a logger’s built-in barometer doesn’t count. These sensors qualify:

- ATMOS 41
- ATMOS 41W
- ATMOS 14
- VP-4

##### Create a WBT model

1. On the **Data** page, select **New Data**.
2. Select **Wet Bulb Temperature** as the type.
3. Select one or more data sources from supported sensors.
4. Edit the data color.
5. Edit the data name.
6. Select **Create** to finish.

The new data will now appear in your data list. On charts, Wet Bulb Temperature shares the air-temperature axis, so the two can be read against each other directly.

##### How WBT is computed

ZENTRA Cloud calculates wet-bulb temperature for every reading that reports air temperature, humidity, and atmospheric pressure. It needs no wind speed, solar radiation, or device location.

1. **Humidity.** ZENTRA uses the sensor’s vapor pressure, e, capped at the saturation vapor pressure es(Ta), where es(T) = 0.611·exp\[17.502·T / (T + 240.97)] kPa and Ta is air temperature. This is the same as relative humidity capped at 100 %. ZENTRA uses saturation over liquid water at every temperature, including below 0 °C. Below freezing, values can therefore differ slightly from calculations that use saturation over ice.
2. **Wet-bulb temperature.** Tw is the psychrometric wet-bulb temperature: the value that satisfies the equation below, where P is the sensor’s own atmospheric pressure in kPa. ZENTRA solves it by iteration.

```
e = es(Tw) − 0.000666·P·(Ta − Tw)
```

This is the same calculation ZENTRA uses for the wet-bulb input to WBGT.

**Psychrometric vs. natural wet bulb.** The psychrometric wet bulb is the reading of a well-ventilated wet thermometer shaded from the sun. A WBGT meter uses a natural wet bulb instead: an exposed, unventilated wick. That wick reads higher than the psychrometric value, most of all in sun and light wind. If you compare ZENTRA’s Wet Bulb Temperature with the wet-bulb channel of a WBGT meter, expect ZENTRA’s value to be lower in those conditions.

**When wet-bulb temperature is missing.** A reading has a wet-bulb temperature only when air temperature, humidity, and pressure are all valid.

ZENTRA runs the calculation at the sensor’s full precision. Values are rounded to 0.1° only for display and export, in the organization’s chosen unit. Hourly and daily values are the average, minimum, and maximum of the per-reading value.